MONITOR CO2 MK9 SET 4 A

Part Number 83000601
Overview

Co2 MK9 detector + Central Unit Mk9 +Horn/Strobe Amber LED + 10m power/ communication cable + power supply + plug lock +5m sinlisation cable +1 RJ45 1-1 connector +1 RJ45 1-2 connector +manual + central unit + h/s sign


Read More...
- +
Share on:
Co2 MK9 detector + Central Unit Mk9 +Horn/Strobe Amber LED + 10m power/ communication cable + power supply + plug lock +5m sinlisation cable +1 RJ45 1-1 connector +1 RJ45 1-2 connector +manual + central unit + h/s sign
Power consumption No alarm status: 56 mA. Alarm status: 68 mA (external optional warning lamp not included)
Wiring connections RJ 45
Digital interface RS485 serial port MODBUS
Outputs 2 x transistor output 24V DC, Min 1 mA
Display LCD
Acoustic signal-strength 76 dBa (1m) max.
Operating principle Non-dispersive infrared (NDIR) and thermistor
CO2 measuring range 0-3 Vol.%
Extended CO2 range: 3-6,7 Vol.%
Gas sampling mode Diffusion
TWA (Time Weighted Average) Calculation 8 h time span (most recent) with 2 min sample period. (Pat. Pend.)
Temperature ±1°C (±1.8°F)
Resolution 1°C (1.8°F)
CO2 ±5% of measured value plus a pressure dependence of +1.6% of reading per kPa/0.295 InHg at 0-40°C (32-102°F).
Resolution 0.01 Vol.%
Annual zero point drift <0.01 Vol.% with automatic self calibration feature
Ambient temperature -20 to +50°C (-4 to +122°F). Only for indoor use.
Compliance with 2004/108/EG Sensor
Life expectancy > 15 years
Operating humidity range 0 to 95% RH (non condensing)
Warm-up time (@ 22°C) 1 min.
Dimensions (LxWxD) 90 x 161 x 38 mm / 3.5” x 6.3” x 1.5”
Ingress protection IP54 according to TÜV, IP44 according to UL
Overvoltage Category II
Pollution degree: II

Overview

Co2 MK9 detector + Central Unit Mk9 +Horn/Strobe Amber LED + 10m power/ communication cable + power supply + plug lock +5m sinlisation cable +1 RJ45 1-1 connector +1 RJ45 1-2 connector +manual + central unit + h/s sign

SPECIFICATION

Power consumption No alarm status: 56 mA. Alarm status: 68 mA (external optional warning lamp not included)
Wiring connections RJ 45
Digital interface RS485 serial port MODBUS
Outputs 2 x transistor output 24V DC, Min 1 mA
Display LCD
Acoustic signal-strength 76 dBa (1m) max.
Operating principle Non-dispersive infrared (NDIR) and thermistor
CO2 measuring range 0-3 Vol.%
Extended CO2 range: 3-6,7 Vol.%
Gas sampling mode Diffusion
TWA (Time Weighted Average) Calculation 8 h time span (most recent) with 2 min sample period. (Pat. Pend.)
Temperature ±1°C (±1.8°F)
Resolution 1°C (1.8°F)
CO2 ±5% of measured value plus a pressure dependence of +1.6% of reading per kPa/0.295 InHg at 0-40°C (32-102°F).
Resolution 0.01 Vol.%
Annual zero point drift <0.01 Vol.% with automatic self calibration feature
Ambient temperature -20 to +50°C (-4 to +122°F). Only for indoor use.
Compliance with 2004/108/EG Sensor
Life expectancy > 15 years
Operating humidity range 0 to 95% RH (non condensing)
Warm-up time (@ 22°C) 1 min.
Dimensions (LxWxD) 90 x 161 x 38 mm / 3.5” x 6.3” x 1.5”
Ingress protection IP54 according to TÜV, IP44 according to UL
Overvoltage Category II
Pollution degree: II